For more information      sales@west-technology.co.uk        +44 (0)1454 329898

Vacuum Brazing

Automated Test Cycle  •  Simple to Use  •  Fast Cycle Time

CASE STUDY:

Contracted to design and manufacture an oil-free high vacuum RF induction brazing system.

The design brief was for one high vacuum system and two process chambers to ensure continuous processing.

Your Title Goes Here

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Specification

Operating Vacuum Pressure:       10-6 mbar

High Vacuum Pump:                      Pfeiffer HiPace 300 turbomolecular pump

Roughing/Backing Pump:             Pfeiffer ACP28 dry running pump

Temperature Measurement:         Type K thermocouple

System Cooling:                                Air

Inert Gas Purge:                               N2/Ar

System Control:                                PLC controlled

                                                             Full colour touch screen 

                                                             Semi-automatic/manual operation

                                                             Data monitoring

                                                             Built in safety interlocks

Power Supply:                                  220 Volt 50Hz, single phase

Pneumatic Supply:                          80-100 psi (virtually zero flow)

Space Envelope:                               1.7m (w) x 1.0m (d) x 1.9m (h)